HIGH PERFORMANCE LIQUID CHROMATOGRAPHY COUPLED
- With DAD, FD and RID:
- Quaternary Pump: Maximum pressure 600bar. Includes quaternary pump, column, connecting capillaries, solvent cabinet, solvent bottles and CAN cable.
- Advanced Software: Lab Advisor Advanced Software includes Data Sharing, Traceability, Advanced EMF and full instrument control with signal plot.
- Refractive Index Detector: includes 8 ul flow cell and LAN interface and twisted pair cable
- Fluorescence Detector: For programmable single wavelength detection (excitation and emission) up to 74 Hz data rate. Includes standard flow cell, 8 μL
- Software = All CDs for instrument and detector connections and workstations, connections
- Computer and Printer = Yes
- Performance specification for RID = Short-term noise: ±2.5 × 10 -9 RIU; Drift: 200 x 10-9 RIU/h; Refractive index range, 1.00–1.75, calibrated; Flow cell: 8 μl, max. 5 bar Accessories = all other important accessories recommended by the company must be supplied. Warranty period, installation and familiarization must also be part of it. column = Three different column (C18, amino column and C8 column) with dimension of 3.0x150mm, 2.7μm.
- Guard column, one for each column type must be supplied Vialsampler = Two drawers, each 66 sample vials (2mL) 132 vials total capacity; Standard needle flush port and peristaltic pump; Default setup with 100μl loop and 100 μL analytical head;
- Multicolumn Thermostat (MCT) = pre-column solvent heating. Temperature range: 10°C below ambient to 85°C Diode Array Detector WR = Provides 120 Hz data acquisition rate RFID tags for flow cell and lamp. Includes long-life deuterium and tungsten lamp.
- Standard flow cell. = Includes stainless steel flow cell with 10-mm path length and 13uL volume. Pressure tight up to 120 bar.
- FLD light source = Xenon Flash Lamp, normal mode 20 W economy mode 5 W, lifetime 4000 h
- HPLC System Tool Kit = Includes plastic syringe, syringe adapter, mounting tool for flangeless nut; wrenches, insert tool, Luer/barb adapter, hex keys, screwdrivers, blank nut long, technical note
- Consumables for Quaternary Pumps = In-Line filter, 2mm 0.2μL filter; In-Line filter, 4.6mm, 0.2μL filter; Solvent inlet filter, SST; Solvent reservoir 1L; Solvent reservoir 1L amber; Bottle head assembly
- FLD performance specification = RAMAN (H2O) > 500 (noise reference measured at signal), Ex=350 nm, Em=397 nm, dark value 450 nm, standard flow cell, 296 Hz for single signal mode 74 Hz for economy mode, Range: settable 200 nm - 1200
- nm and zero-orde r, Monochromator: concave holographic grating, F/1.6, blaze: 300 nm
- Additional accessory 1 = one amino column with its guad column
- Additional accessory 2 = Septa for 6 mm screw cap vial 100/pk
- Additional accessory 3 = Screw cap for 6ml Vials 100/pk Additional accesary 4 = Vial, 5 ml High recovery vial, 30/pk
- Includes installation, user training and 2-years warranty.